When oil pipe lines require repair it usually requires welding. This quick video walks you through the steps involved in moving the log data to your PC and using GE Panalog Viewer software for analysis and reporting purposes. gncelleniyor Arama sonularn eletirin: To properly program a PT878 for flow measurement, you'll need to input the thickness of your pipe wall. Ultrasonic or Acoustic Couplants and Alternatives zet: View and Download GE TransPort PT878 user manual online. It can cope with a percentage of impurities however the more particles in the liquid the less likely the technique will work! %%EOF
The 'time of flight' measurement technique relies on the fluid being relatively clean. 138 0 obj
<>
endobj
Does the liquid fill the pipe?
Watch this short video for instructions and diagnostic standards. gncelleniyor Arama sonularn eletirin: PT878 Specifications GE Sensing Fluid Types Acoustically conductive fluids, including most clean liquids, and many liquids with entrained solids or gas bubbles. This video explains how to select single or multiple display viewing and change the display parameters for each individual view to best suit your application needs. Misalignment.
GE Panametrics TransPort PT878 Ultrasonic Flow Meter, PanaView for the PT878 - GE Measurement & Control, Panametrics TransPort PT878 liquid flowmeter, Transport PT878 GE Portable Liquid Ultrasonic Flowmeter Manual, TransPort PT878 Panametrics Portable Ultrasonic Liquid Flowmeter, TransPort PT878 Portable Ultrasonic Liquid Flow Meter Brochure 280 KB, Extech Instruments TKG100 Digital Ultrasonic Thickness Gauge Quick Start Guide, Extech Instruments TKG250 Digital Ultrasonic Thickness Gauge/Datalogger Quick Start Guide, Extech Instruments TKG150 Digital Ultrasonic Thickness Gauge/Datalogger Quick Start Guide, Extech Instruments TKG100, TKG150 Quick Start Manual, 3.6.1 Path Parameters for Clamp-On Transducers, 3.6.2 Path Parameters for Wetted Transducers, 3.7 Entering the Energy Option Parameters, 3.7.1 Entering Inputs in the Energy Option, 3.7.2 Entering Custom Cp Data in the Energy Option, 3.8.1 Entering General-Purpose Analog Inputs, 3.8.2 Entering Analog Inputs in the Energy Option, 4.1.4 Saving a Site with a Different Name, 4.1.9 Transfer Files Between the PT878 and a PC, 4.1.11 Listing Files in Chronological Order, 5.5.1 Specifying the Number of Displayed Parameters, 5.6.2 Transferring a File from a PC to the PT, 5.6.6 Listing Files in Chronological Order, 5.7 Accessing Meter Data The About Option, 6.12Taking a Bitmap Capture of a Current Screen, 7.5.2 Displaying Log Data in Graphical Form, 7.5.3 Displaying Log Data in Spreadsheet Form, 7.6.2 Listing Logs in Chronological Order, 8.4.1 Entering the Material and Soundspeed, 8.4.2 Measuring Thickness in Numeric Format, 8.4.3 Displaying the Receive Signal in Graphical Format, 8.4.4 Calibrating the Thickness Gauge Transducer, 8.4.5 Calculating Velocity (Pipe Material Soundspeed), 8.7 Calibrating the Analog Output and Inputs, 8.10.3 Testing the Watchdog Timer Circuit, 8.11Resetting to Factory Default Parameters, 10.1.4 Flow Accuracy (Velocity, % of reading), 10.4.1 Clamp-On Ultrasonic Flow Transducers, C.3.1 Connecting the RTD to the 4 to 20-mA Transmitter, C.3.2 Connecting the Transmitter to the PT, D.1 Factors Affecting Performance and Accuracy, D.1.4 Acoustic Properties of the Material. A PT878 was connected to the outfall of the tank. 0000011222 00000 n Solid particles and gas bubbles absorb and disperse ultrasound. <<149B0267D26A48478ECA0AD844B8D0F1>]/Prev 1062167>> endstream endobj 139 0 obj <>>> endobj 140 0 obj <>/ExtGState<>/Font<>/ProcSet[/PDF/Text/ImageC]/XObject<>>>/Rotate 0/TrimBox[0 25.2 612 817.2]/Type/Page>> endobj 141 0 obj <>stream 0000011970 00000 n If the sound speed measured by the PT878 differs significantly from the expected sound speed for the fluid in question, it indicates a problem with meter configuration or transducer installation. For the best experience on our site, be sure to turn on Javascript in your browser. If GE Infrastructure Sensing did not supply your flowcell, the dimensions you program must be consistent with the required flow accuracy. Page 119 Then press to open the File Menu, and scroll to [MENU] the appropriate option, as shown in Figure 67 above. This compact, lightweight kit includes a rechargeable internal battery pack and universal power sup https://phohen.com/tr/post-detail/transport-pt878---instrumart/518933500, GE TRANSPORT PT878 USER MANUAL Pdf Download, https://phohen.com/tr/post-detail/ge-transport-pt878-user-manual-pdf-download/518933501, The TransPort PT878 Liquid Flowmeter - User Equip, https://phohen.com/tr/post-detail/the-transport-pt878-liquid-flowmeter---user-equip/518933502, TransPort PT878 - Baker Hughes Digital Solutions, https://phohen.com/tr/post-detail/transport-pt878---baker-hughes-digital-solutions/518933503, Panaview for the PT878 Operating Manual English, https://phohen.com/tr/post-detail/panaview-for-the-pt878-operating-manual-english/518933504, https://phohen.com/tr/post-detail/transport-pt878---cloudinary/518933505, Manuals, Guides & Specifications for Technicians | Userequip, https://phohen.com/tr/post-detail/manuals-guides--specifications-for-technicians--userequip/518933506, GE Sensing & Inspection Technologies - Instrumart, https://phohen.com/tr/post-detail/ge-sensing--inspection-technologies---instrumart/518933507, GE Sensing & Inspection Technologies - ATECorp.com, https://phohen.com/tr/post-detail/ge-sensing--inspection-technologies---atecorpcom/518933508, https://phohen.com/tr/post-detail/ge-panametrics-ultrasonic-flow-meter/518933509, GE Panametrics TransPort PT878 Flowmeter | ATEC, https://phohen.com/tr/post-detail/ge-panametrics-transport-pt878-flowmeter--atec/518933510, https://phohen.com/tr/post-detail/r-ge-panametrics-ultrasonic-flow-meter/518933511, https://phohen.com/tr/post-detail/transport-pt878---dambakerhughesdscom/518933512, Tutorial: GE Panametrics TransPort PT878 Portable Ultrasonic , https://phohen.com/tr/post-detail/tutorial-ge-panametrics-transport-pt878-portable-ultrasonic-/518933513, Manual Ge Panametrics Transport Pt878 [ylyx9kqpjznm], https://phohen.com/tr/post-detail/manual-ge-panametrics-transport-pt878-ylyx9kqpjznm/518933514, https://phohen.com/tr/post-detail/transport-pt878---veronics/518933515, Atec PT878 User Manual - ManualMachine.com, https://phohen.com/tr/post-detail/atec-pt878-user-manual---manualmachinecom/518933516, TRANSPORT PT878 FLOWMETER O A S - TechRentals, https://phohen.com/tr/post-detail/transport-pt878-flowmeter-o-a-s---techrentals/518933517, GE Panametrics TransPort PT878 Ultrasonic Flow Meter System, https://phohen.com/tr/post-detail/ge-panametrics-transport-pt878-ultrasonic-flow-meter-system/518933518. 0000017975 00000 n
If the ATECorp.com is the leading supplier of test and measurement instruments. gncelleniyor interface with multiple Panametrics instruments.
0000018653 00000 n %PDF-1.7 %
Using the temperature transducers and the flow meter you can measure the energy of a chilled water system. This section describes the TransPort features and general system, and explains the theory of operation. 0000018801 00000 n Pipe Sizes 0.5 in to 300 in (12.7 mm to 7.6 m) and larger Hakknda makaleler Atec PT878 User Manual - ManualMachine.com. The bond between the crystal and the case may be damaged by extreme shock and by temperature extremes. can be used if the temperature is not sufficient to make it run out from under the transducers and or be workable in overhead applications. 0000018610 00000 n Calculating Flow Rate for Different Valve Settings 0000001556 00000 n Ultrasonic gel can usually be purchased from veterinary supplies or those larger pet warehouses. 0000018212 00000 n The PT878 and its transducers are designed for use in general-purpose locations only. Hakknda makaleler GE Panametrics Ultrasonic Flow Meter. It explains how to use the LEMO and BNC connectors, as well as which cables are used for the upstream (red-label) and downstream (blue-label) ultrasonic sensors. 0000019311 00000 n In this video, rental specialist Nolan shows you all the parts of RAECO Rent's PT878 rental kit, how it fits in the kit, and how to repack it for shipping. These are both under different items in the 'Program' menu. 0000019225 00000 n This document focuses on particular applications of PanaView for the PT878 flowmeter. Pipes with extremely thick walls or high OD to ID ratios may also present difficulties.
hbbd``b`6@i#`b@ V&bf $Hl'% "^-@+ Press Enterto accept the entry.
For general PanaView applications such as creating graph and log files, displaying live measurement data, and creating custom templates, please refer to the general PanaView Users Manual (910-211). Hakknda makaleler TransPort PT878 - Cloudinary.
gncelleniyor Panametrics, Inc. 221 Crescent Street, Suite 1 Waltham, MA 02453-3497, USA Tel 781-899-2719Toll-Free 800-833-9438 Fax 781-894-8582 E-mail, The GE Panametrics TransPort PT878 flow meter system is a highly versatile, self-contained, portable ultrasonic kit with all the options and accessories to meet all your liquid flow measurement needs. This compact, lightweight kit includes a rechargeable internal battery pack and universal power sup Makaleye balant: https://phohen.com/tr/post-detail/ge-panametrics-transport-pt878-ultrasonic-flow-meter-system/518933518. Usually the connector on the transducer is the part that is damaged, as it is the most fragile. zet: ATECorp.com is the leading supplier of test and measurement instruments. 0000018955 00000 n Here one can find information about many different types of Makaleye balant: https://phohen.com/tr/post-detail/manuals-guides--specifications-for-technicians--userequip/518933506. 0000011506 00000 n Before purchasing, consider temperature and usability for overhead applications (viscosity) as some are very fluid at ambient temperature. However, these flowmeters will often work anyway. gncelleniyor PT878 Panametrics Portable Liquid Ultrasonic Flowmeter Applications The TransPort PT878 portable liquid flowmeter is a complete portable ultrasonic flow metering system for measurement of: Potable water Wastewater Cooling and heating water Ultrapure water and liquids Water/glycol solutions Crude oil Refined hydrocarbons Hakknda makaleler TRANSPORT PT878 FLOWMETER O A S - TechRentals. All metals and most plastics. 0000018326 00000 n 0000018412 00000 n Is the liquid clean? 0000018912 00000 n The flow was measured and recorded for each rotation of the valve. %%EOF 0000018455 00000 n 0000012040 00000 n
gncelleniyor GE Panametrics: Model: PT878 : Dealer: User Equip: File: Panametrics PT878 Manual.pdf Share technical documentation including product manuals, getting started guides, and specifications. 0000004878 00000 n Internal diagnostic and troubleshooting features help isolate and remedy common flowcell and transducer problems. Makaleye balant: https://phohen.com/tr/post-detail/transport-pt878---baker-hughes-digital-solutions/518933503.
Loose scale and thick coatings (such as tar or oil) will interfere with ultrasound transmission and may result in incorrect or unreliable measurements. The flowcell orientation must not allow sediment or gas entrapment at the transducer locations. 0000004156 00000 n
Log Water Consumption on Site 0000016933 00000 n 0000000016 00000 n However, because this is a remote site the PT878 flow meter must be connected to a remote dc source. 0000018369 00000 n 0 The GE thickness gauge does this for you, but will first need to be calibrated.
More details. The pipe and transducer must be clean and dry for permanent couplant, such as grease or epoxy, to adhere properly. Clamp-on transducers must be in intimate contact with the pipe. gncelleniyor Download & View Manual Ge Panametrics Transport Pt878 as PDF for free. If the sound speed measured by the PT878 differs significantly from the expected sound speed for the fluid in question, it indicates a problem with meter configuration or transducer installation. If the connector cannot be repaired, replace the transducers. 423 63 Check your pipe for wall thickness, diameter, dents, eccentricity, weld deformity, and straightness. zet: Hakknda makaleler TransPort PT878 - Cloudinary. Gas Flow Meter Selection (Google Spreadsheet) From these measurements the logger can derive the energy figure for the system. The flowmeter is attached to the incoming water line. Some pipe materials or linings such as Fibreglass (or generic fibre reinforced pipe), Teflon, and polyethylene, absorb ultrasound and may cause problems in clamp-on applications. 0000002984 00000 n zet: Hakknda makaleler TransPort PT878 - Baker Hughes Digital Solutions. 0000016850 00000 n The TransPort will tolerate relatively wide, but slow, changes in fluid sound speed due to changes in fluid composition and temperature. The Panametrics PT878 is capable of displaying up to four views simultaneously on the main display screen. 0000007960 00000 n Words: 23,543; Pages: 97; Preview; Full text; GE Sensing & Inspection Technologies Transport PT878 Caudalmetro ultrasnico integrado porttil Manual abreviado GE Makaleye balant: https://phohen.com/tr/post-detail/manual-ge-panametrics-transport-pt878-ylyx9kqpjznm/518933514. This technique has an advantage such that if it does work then you can believe the reading. Overview The TransPort measures acoustically conductive single-phase fluids. Makaleye balant: https://phohen.com/tr/post-detail/the-transport-pt878-liquid-flowmeter---user-equip/518933502. X The GE thickness gauge does this for you, but will first need to be calibrated. Press . Displaying And Configuring Data, Page 114: Specifying The Number Of Displayed Parameters, Page 118: Managing Files - The Drive Manager, Page 121: Transferring A File From A Pc To The Pt878, Page 126: Accessing Meter Data -The About Option, Page 127: Chapter 6. Features and Capabilities 2 TransPort PT878 Users Manual 1.1 Overview (cont.) Cavitation can usually be controlled through proper installation design. Instrument Manual (pdf)
To do this we use the standard charger supplied with the unit and an inverter. GE Panametrics PT878 Ultrasonic Liquid Flow Meter, Sound Speed and Kinematic Viscosity table (pdf), Power Point Introduction to the PT878 Flowmeter (pdf), Gas Flow Meter Selection (Google Spreadsheet), 4 Carbon steel schedule 80 pipe 400 psig gas at 105 ft/s. %PDF-1.4 % The diameter and wall thickness. If you are going to weld a pipe containing fuel oil the pipe MUST be full and flowing in order to ensure there is no gas present and to ensure there is no build up in heat. 0000017377 00000 n 0000017420 00000 n This will save you time when you take multiple measurements from the same site over a period of time. 0000008130 00000 n This video walks you through the proper way to connect and disconnect cables between the GE PT878 and the included ultrasonic transducers. gncelleniyor To properly program a PT878 for flow measurement, you'll need to input the thickness of your pipe wall. You'll walk through adjusting the clamping fixtures to the proper spacing, understanding ideal location of the transducer installation on the pipe for best ultrasonic sound propagation. Physical damage. To discuss a rental or rental purchase plan 2022 by Advanced Test Equipment Corp. All Rights Reserved. 0000003098 00000 n The fluid must be homogenous, single phase, relatively clean, and flowing steadily. The transducer transmits relatively narrow beams of ultrasound, and therefore transducer alignment is critical to assure that the beam can travel from one transducer to the other without undue attenuation. Also, be sure that the transducer spacing agrees with the calculated spacing (S). hb```f``J``c`a`@ V dapn8_`u,arWW30xE];|\YcF[7xq6 >%9/x*osKi;Qbqh```` 2# J`A0@ The store will not work correctly in the case when cookies are disabled.
After the PT878 meter has been programmed and a measurement taken, you can save the programming of a site to the PT878 flowmeter. Arama sonularn eletirin: The GE Panametrics TransPort PT878 flow meter system is a highly versatile, self-contained, portable ultrasonic kit with all the options and accessories to meet all your liquid flow measurement needs. Finally, the video walks you through applying couplant to the transducers, installing the transducers on the clamping fixtures, and securing the hardware properly before connecting the transducer cables. gncelleniyor Measure with PT878 thickness gauge. 0000018124 00000 n 159 0 obj <>/Filter/FlateDecode/ID[]/Index[138 36]/Info 137 0 R/Length 98/Prev 230241/Root 139 0 R/Size 174/Type/XRef/W[1 2 1]>>stream The crystal itself can also be damaged by the same conditions.
The pipe wall must be smooth and generally free of paint. gncelleniyor Hakknda makaleler Manuals, Guides & Specifications for Technicians | Userequip. The unit plus an inverter draw 1.35 A so a 120 A/hr battery would last 3.5 days. : zet: Hakknda makaleler TransPort PT878 - Instrumart. gncelleniyor Arama sonularn eletirin: Para assegurar o funcionamen to seguro do PT878, deve instal-lo e utiliz-lo tal como descrito neste manual. Diagnostics And Troubleshooting, Page 222: Displaying Diagnostic Parameters, Page 255: Appendix B. Get the most out of your PT878 portable liquid ultrasonic flowmeter. Poor coupling to pipe. TransPort Portable Liquid Flowmeter. zet: Hakknda makaleler TransPort PT878 - dam.bakerhughesds.com. Prepare for your tests by watching these training videos, each focusing on a key function of your testing process, from startup to reporting. The Energy Option also needs to be enabled as does the appropriate scaling of the analogue input. What is the pipe made of and what is the sound speed in that material?
Transducer Tab 1. Please note, some accessories shown in the video are not included in RAECO Rents' flowmeter kit. Are there 5 pipe diameters downstream from where the flowmeter is to be mounted? ACr5|}U?h H<8H:cq`EA3` H! Ensuring There Is Flow in a Pipe Carrying Fuel Oil Prior To Welding Excessive build-up of scale, rust, or debris will interfere with flow measurement.
O PT878 e os seus transdutores so concebidos apenas Makaleye balant: https://phohen.com/tr/post-detail/ge-sensing--inspection-technologies---instrumart/518933507. In some cases different transducers may be used that protrude into the flow stream. @{) 2h,Lgh3% $ -O({U%v8. gncelleniyor To ensure the safe operation of the PT878, you must install and operate it as described in this manual. I have found that good quality high temp wheel bearing grease is usually a suitable alternative. The following are applications using the PT878 flow meter where nitrogen gas flow has been measured: Measuring Flow in a Pipe Carrying Superheated Steam The sound speed can be determined using the Sound Speed and Kinematic Viscosity table (pdf), Also, if the pipe material is not amongst the standard pipe material pre-loaded in the device, you may need to use the sound speed information in the Pipe Material Sound Speed table (pdf). gncelleniyor Makaleye balant: https://phohen.com/tr/post-detail/transport-pt878---instrumart/518933500. The TransPort PT878's patented Correlation Transit-Time digital signal processing (DSP) technique greatly increases its signal-to-noise ratio for accurate, drift-free flow measurement in liquids that contain a second phase of entrained solids or gas bubbles. 0 This video walks you through calibrating the thickness gauge and testing the results, so you know your pipe measurement will be accurate. Makaleye balant: https://phohen.com/tr/post-detail/tutorial-ge-panametrics-transport-pt878-portable-ultrasonic-/518933513. The inside of the pipe or flowcell must be relatively clean. Glycerin can give a few extra dB of coupling (it can sometimes help obtain useful readings when there seems to be no reason why it won't work) as its acoustic impedance is similar to plastics, but it can cause corrosion and or rusting so it must be completely removed. 0000016103 00000 n The TransPort PT878 operates in these and other difficult applications where conventional transit time flow meters fail. The calibration is done in the 'Setup>Calibrate' menu The GE Panametrics TransPort PT878's compact size, lightweight, rechargeable internal battery pack and universal power supply charger make it the ideal go-anywhere flow meter. gncelleniyor Para assegurar o funcionamen to seguro do PT878, deve instal-lo e utiliz-lo tal como descrito neste manual. This video explains how to install clamp-on ultrasonic transducers onto a pipe, using the information you programmed into the system based on pipe size and thickness, media type and temperature, and pipe traverses. 0000003549 00000 n Para alm disso, certifique-se de que todos os cdigos de segurana aplicveis e regulaes para instalao de equipamento elctrico na sua rea so respeitados. 2. Unless You are Prepared, Demonstration: How to Make Your TSI Quest Edge Dosimeter Microphone Last Longer, Demonstration: Setting Up TSI DusTrak Enclosures, Regional Emphasis Program for Transportation Tank Cleaning Operations, Protecting Workers Exposed to Wildfire Smoke, California EPA Community Air Monitoring Plan Guidance, Oregon OSHA Emergency Heat Illness Prevention, CDPH Frequently Asked Questions for Contractors, Tutorial: GE Panametrics TransPort PT878 Portable Ultrasonic Flowmeter. zet: Hakknda makaleler Atec PT878 User Manual - ManualMachine.com. The TransPort PT878 is suited for all standard transit Makaleye balant: https://phohen.com/tr/post-detail/ge-panametrics-transport-pt878-flowmeter--atec/518933510. Pipe Sizes 0.5 in to 300 in (12.7 mm to 7.6 m) and larger Makaleye balant: https://phohen.com/tr/post-detail/transport-pt878---veronics/518933515. gncelleniyor Arama sonularn eletirin: interface with multiple Panametrics instruments. endstream endobj startxref Programming Meter Settings, Page 133: Changing Date And Time Appearance, Page 139: Changing Communications Settings, Page 142: Resetting Forward And Reverse Totals, Page 146: Taking A Bitmap Capture Of A Current Screen, Page 156: Copying (Cloning) A Selected Log, Page 166: Displaying Log Data In Graphical Form, Page 169: Displaying Log Data In Spreadsheet Form, Page 178: Measuring Thickness In Numeric Format, Page 179: Displaying The Receive Signal In Graphical Format, Page 181: Calibrating The Thickness Gauge Transducer, Page 184: Calculating Velocity (Pipe Material Soundspeed), Page 186: Programming The Thickness Gauge, Page 189: Displaying Diagnostic Parameters, Page 190: Calibrating The Analog Output And Inputs, Page 206: Testing The Watchdog Timer Circuit, Page 208: Taking Wave Samples For Diagnosis, Page 210: Resetting To Factory Default Parameters, Page 219: Chapter 9.

GE Panametrics TransPort PT878 Ultrasonic Flow Meter, PanaView for the PT878 - GE Measurement & Control, Panametrics TransPort PT878 liquid flowmeter, Transport PT878 GE Portable Liquid Ultrasonic Flowmeter Manual, TransPort PT878 Panametrics Portable Ultrasonic Liquid Flowmeter, TransPort PT878 Portable Ultrasonic Liquid Flow Meter Brochure 280 KB, Extech Instruments TKG100 Digital Ultrasonic Thickness Gauge Quick Start Guide, Extech Instruments TKG250 Digital Ultrasonic Thickness Gauge/Datalogger Quick Start Guide, Extech Instruments TKG150 Digital Ultrasonic Thickness Gauge/Datalogger Quick Start Guide, Extech Instruments TKG100, TKG150 Quick Start Manual, 3.6.1 Path Parameters for Clamp-On Transducers, 3.6.2 Path Parameters for Wetted Transducers, 3.7 Entering the Energy Option Parameters, 3.7.1 Entering Inputs in the Energy Option, 3.7.2 Entering Custom Cp Data in the Energy Option, 3.8.1 Entering General-Purpose Analog Inputs, 3.8.2 Entering Analog Inputs in the Energy Option, 4.1.4 Saving a Site with a Different Name, 4.1.9 Transfer Files Between the PT878 and a PC, 4.1.11 Listing Files in Chronological Order, 5.5.1 Specifying the Number of Displayed Parameters, 5.6.2 Transferring a File from a PC to the PT, 5.6.6 Listing Files in Chronological Order, 5.7 Accessing Meter Data The About Option, 6.12Taking a Bitmap Capture of a Current Screen, 7.5.2 Displaying Log Data in Graphical Form, 7.5.3 Displaying Log Data in Spreadsheet Form, 7.6.2 Listing Logs in Chronological Order, 8.4.1 Entering the Material and Soundspeed, 8.4.2 Measuring Thickness in Numeric Format, 8.4.3 Displaying the Receive Signal in Graphical Format, 8.4.4 Calibrating the Thickness Gauge Transducer, 8.4.5 Calculating Velocity (Pipe Material Soundspeed), 8.7 Calibrating the Analog Output and Inputs, 8.10.3 Testing the Watchdog Timer Circuit, 8.11Resetting to Factory Default Parameters, 10.1.4 Flow Accuracy (Velocity, % of reading), 10.4.1 Clamp-On Ultrasonic Flow Transducers, C.3.1 Connecting the RTD to the 4 to 20-mA Transmitter, C.3.2 Connecting the Transmitter to the PT, D.1 Factors Affecting Performance and Accuracy, D.1.4 Acoustic Properties of the Material. A PT878 was connected to the outfall of the tank. 0000011222 00000 n Solid particles and gas bubbles absorb and disperse ultrasound. <<149B0267D26A48478ECA0AD844B8D0F1>]/Prev 1062167>> endstream endobj 139 0 obj <>>> endobj 140 0 obj <>/ExtGState<>/Font<>/ProcSet[/PDF/Text/ImageC]/XObject<>>>/Rotate 0/TrimBox[0 25.2 612 817.2]/Type/Page>> endobj 141 0 obj <>stream 0000011970 00000 n If the sound speed measured by the PT878 differs significantly from the expected sound speed for the fluid in question, it indicates a problem with meter configuration or transducer installation. For the best experience on our site, be sure to turn on Javascript in your browser. If GE Infrastructure Sensing did not supply your flowcell, the dimensions you program must be consistent with the required flow accuracy. Page 119 Then press to open the File Menu, and scroll to [MENU] the appropriate option, as shown in Figure 67 above. This compact, lightweight kit includes a rechargeable internal battery pack and universal power sup https://phohen.com/tr/post-detail/transport-pt878---instrumart/518933500, GE TRANSPORT PT878 USER MANUAL Pdf Download, https://phohen.com/tr/post-detail/ge-transport-pt878-user-manual-pdf-download/518933501, The TransPort PT878 Liquid Flowmeter - User Equip, https://phohen.com/tr/post-detail/the-transport-pt878-liquid-flowmeter---user-equip/518933502, TransPort PT878 - Baker Hughes Digital Solutions, https://phohen.com/tr/post-detail/transport-pt878---baker-hughes-digital-solutions/518933503, Panaview for the PT878 Operating Manual English, https://phohen.com/tr/post-detail/panaview-for-the-pt878-operating-manual-english/518933504, https://phohen.com/tr/post-detail/transport-pt878---cloudinary/518933505, Manuals, Guides & Specifications for Technicians | Userequip, https://phohen.com/tr/post-detail/manuals-guides--specifications-for-technicians--userequip/518933506, GE Sensing & Inspection Technologies - Instrumart, https://phohen.com/tr/post-detail/ge-sensing--inspection-technologies---instrumart/518933507, GE Sensing & Inspection Technologies - ATECorp.com, https://phohen.com/tr/post-detail/ge-sensing--inspection-technologies---atecorpcom/518933508, https://phohen.com/tr/post-detail/ge-panametrics-ultrasonic-flow-meter/518933509, GE Panametrics TransPort PT878 Flowmeter | ATEC, https://phohen.com/tr/post-detail/ge-panametrics-transport-pt878-flowmeter--atec/518933510, https://phohen.com/tr/post-detail/r-ge-panametrics-ultrasonic-flow-meter/518933511, https://phohen.com/tr/post-detail/transport-pt878---dambakerhughesdscom/518933512, Tutorial: GE Panametrics TransPort PT878 Portable Ultrasonic , https://phohen.com/tr/post-detail/tutorial-ge-panametrics-transport-pt878-portable-ultrasonic-/518933513, Manual Ge Panametrics Transport Pt878 [ylyx9kqpjznm], https://phohen.com/tr/post-detail/manual-ge-panametrics-transport-pt878-ylyx9kqpjznm/518933514, https://phohen.com/tr/post-detail/transport-pt878---veronics/518933515, Atec PT878 User Manual - ManualMachine.com, https://phohen.com/tr/post-detail/atec-pt878-user-manual---manualmachinecom/518933516, TRANSPORT PT878 FLOWMETER O A S - TechRentals, https://phohen.com/tr/post-detail/transport-pt878-flowmeter-o-a-s---techrentals/518933517, GE Panametrics TransPort PT878 Ultrasonic Flow Meter System, https://phohen.com/tr/post-detail/ge-panametrics-transport-pt878-ultrasonic-flow-meter-system/518933518. 0000017975 00000 n
If the ATECorp.com is the leading supplier of test and measurement instruments. gncelleniyor interface with multiple Panametrics instruments.
0000018653 00000 n %PDF-1.7 %
Using the temperature transducers and the flow meter you can measure the energy of a chilled water system. This section describes the TransPort features and general system, and explains the theory of operation. 0000018801 00000 n Pipe Sizes 0.5 in to 300 in (12.7 mm to 7.6 m) and larger Hakknda makaleler Atec PT878 User Manual - ManualMachine.com. The bond between the crystal and the case may be damaged by extreme shock and by temperature extremes. can be used if the temperature is not sufficient to make it run out from under the transducers and or be workable in overhead applications. 0000018610 00000 n Calculating Flow Rate for Different Valve Settings 0000001556 00000 n Ultrasonic gel can usually be purchased from veterinary supplies or those larger pet warehouses. 0000018212 00000 n The PT878 and its transducers are designed for use in general-purpose locations only. Hakknda makaleler GE Panametrics Ultrasonic Flow Meter. It explains how to use the LEMO and BNC connectors, as well as which cables are used for the upstream (red-label) and downstream (blue-label) ultrasonic sensors. 0000019311 00000 n In this video, rental specialist Nolan shows you all the parts of RAECO Rent's PT878 rental kit, how it fits in the kit, and how to repack it for shipping. These are both under different items in the 'Program' menu. 0000019225 00000 n This document focuses on particular applications of PanaView for the PT878 flowmeter. Pipes with extremely thick walls or high OD to ID ratios may also present difficulties.
hbbd``b`6@i#`b@ V&bf $Hl'% "^-@+ Press Enterto accept the entry.

gncelleniyor Panametrics, Inc. 221 Crescent Street, Suite 1 Waltham, MA 02453-3497, USA Tel 781-899-2719Toll-Free 800-833-9438 Fax 781-894-8582 E-mail, The GE Panametrics TransPort PT878 flow meter system is a highly versatile, self-contained, portable ultrasonic kit with all the options and accessories to meet all your liquid flow measurement needs. This compact, lightweight kit includes a rechargeable internal battery pack and universal power sup Makaleye balant: https://phohen.com/tr/post-detail/ge-panametrics-transport-pt878-ultrasonic-flow-meter-system/518933518. Usually the connector on the transducer is the part that is damaged, as it is the most fragile. zet: ATECorp.com is the leading supplier of test and measurement instruments. 0000018955 00000 n Here one can find information about many different types of Makaleye balant: https://phohen.com/tr/post-detail/manuals-guides--specifications-for-technicians--userequip/518933506. 0000011506 00000 n Before purchasing, consider temperature and usability for overhead applications (viscosity) as some are very fluid at ambient temperature. However, these flowmeters will often work anyway. gncelleniyor PT878 Panametrics Portable Liquid Ultrasonic Flowmeter Applications The TransPort PT878 portable liquid flowmeter is a complete portable ultrasonic flow metering system for measurement of: Potable water Wastewater Cooling and heating water Ultrapure water and liquids Water/glycol solutions Crude oil Refined hydrocarbons Hakknda makaleler TRANSPORT PT878 FLOWMETER O A S - TechRentals. All metals and most plastics. 0000018326 00000 n 0000018412 00000 n Is the liquid clean? 0000018912 00000 n The flow was measured and recorded for each rotation of the valve. %%EOF 0000018455 00000 n 0000012040 00000 n
gncelleniyor GE Panametrics: Model: PT878 : Dealer: User Equip: File: Panametrics PT878 Manual.pdf Share technical documentation including product manuals, getting started guides, and specifications. 0000004878 00000 n Internal diagnostic and troubleshooting features help isolate and remedy common flowcell and transducer problems. Makaleye balant: https://phohen.com/tr/post-detail/transport-pt878---baker-hughes-digital-solutions/518933503.
Loose scale and thick coatings (such as tar or oil) will interfere with ultrasound transmission and may result in incorrect or unreliable measurements. The flowcell orientation must not allow sediment or gas entrapment at the transducer locations. 0000004156 00000 n
Log Water Consumption on Site 0000016933 00000 n 0000000016 00000 n However, because this is a remote site the PT878 flow meter must be connected to a remote dc source. 0000018369 00000 n 0 The GE thickness gauge does this for you, but will first need to be calibrated.
More details. The pipe and transducer must be clean and dry for permanent couplant, such as grease or epoxy, to adhere properly. Clamp-on transducers must be in intimate contact with the pipe. gncelleniyor Download & View Manual Ge Panametrics Transport Pt878 as PDF for free. If the sound speed measured by the PT878 differs significantly from the expected sound speed for the fluid in question, it indicates a problem with meter configuration or transducer installation. If the connector cannot be repaired, replace the transducers. 423 63 Check your pipe for wall thickness, diameter, dents, eccentricity, weld deformity, and straightness. zet: Hakknda makaleler TransPort PT878 - Cloudinary. Gas Flow Meter Selection (Google Spreadsheet) From these measurements the logger can derive the energy figure for the system. The flowmeter is attached to the incoming water line. Some pipe materials or linings such as Fibreglass (or generic fibre reinforced pipe), Teflon, and polyethylene, absorb ultrasound and may cause problems in clamp-on applications. 0000002984 00000 n zet: Hakknda makaleler TransPort PT878 - Baker Hughes Digital Solutions. 0000016850 00000 n The TransPort will tolerate relatively wide, but slow, changes in fluid sound speed due to changes in fluid composition and temperature. The Panametrics PT878 is capable of displaying up to four views simultaneously on the main display screen. 0000007960 00000 n Words: 23,543; Pages: 97; Preview; Full text; GE Sensing & Inspection Technologies Transport PT878 Caudalmetro ultrasnico integrado porttil Manual abreviado GE Makaleye balant: https://phohen.com/tr/post-detail/manual-ge-panametrics-transport-pt878-ylyx9kqpjznm/518933514. This technique has an advantage such that if it does work then you can believe the reading. Overview The TransPort measures acoustically conductive single-phase fluids. Makaleye balant: https://phohen.com/tr/post-detail/the-transport-pt878-liquid-flowmeter---user-equip/518933502. X The GE thickness gauge does this for you, but will first need to be calibrated. Press . Displaying And Configuring Data, Page 114: Specifying The Number Of Displayed Parameters, Page 118: Managing Files - The Drive Manager, Page 121: Transferring A File From A Pc To The Pt878, Page 126: Accessing Meter Data -The About Option, Page 127: Chapter 6. Features and Capabilities 2 TransPort PT878 Users Manual 1.1 Overview (cont.) Cavitation can usually be controlled through proper installation design. Instrument Manual (pdf)
To do this we use the standard charger supplied with the unit and an inverter. GE Panametrics PT878 Ultrasonic Liquid Flow Meter, Sound Speed and Kinematic Viscosity table (pdf), Power Point Introduction to the PT878 Flowmeter (pdf), Gas Flow Meter Selection (Google Spreadsheet), 4 Carbon steel schedule 80 pipe 400 psig gas at 105 ft/s. %PDF-1.4 % The diameter and wall thickness. If you are going to weld a pipe containing fuel oil the pipe MUST be full and flowing in order to ensure there is no gas present and to ensure there is no build up in heat. 0000017377 00000 n 0000017420 00000 n This will save you time when you take multiple measurements from the same site over a period of time. 0000008130 00000 n This video walks you through the proper way to connect and disconnect cables between the GE PT878 and the included ultrasonic transducers. gncelleniyor To properly program a PT878 for flow measurement, you'll need to input the thickness of your pipe wall. You'll walk through adjusting the clamping fixtures to the proper spacing, understanding ideal location of the transducer installation on the pipe for best ultrasonic sound propagation. Physical damage. To discuss a rental or rental purchase plan 2022 by Advanced Test Equipment Corp. All Rights Reserved. 0000003098 00000 n The fluid must be homogenous, single phase, relatively clean, and flowing steadily. The transducer transmits relatively narrow beams of ultrasound, and therefore transducer alignment is critical to assure that the beam can travel from one transducer to the other without undue attenuation. Also, be sure that the transducer spacing agrees with the calculated spacing (S). hb```f``J``c`a`@ V dapn8_`u,arWW30xE];|\YcF[7xq6 >%9/x*osKi;Qbqh```` 2# J`A0@ The store will not work correctly in the case when cookies are disabled.
After the PT878 meter has been programmed and a measurement taken, you can save the programming of a site to the PT878 flowmeter. Arama sonularn eletirin: The GE Panametrics TransPort PT878 flow meter system is a highly versatile, self-contained, portable ultrasonic kit with all the options and accessories to meet all your liquid flow measurement needs. Finally, the video walks you through applying couplant to the transducers, installing the transducers on the clamping fixtures, and securing the hardware properly before connecting the transducer cables. gncelleniyor Measure with PT878 thickness gauge. 0000018124 00000 n 159 0 obj <>/Filter/FlateDecode/ID[]/Index[138 36]/Info 137 0 R/Length 98/Prev 230241/Root 139 0 R/Size 174/Type/XRef/W[1 2 1]>>stream The crystal itself can also be damaged by the same conditions.
The pipe wall must be smooth and generally free of paint. gncelleniyor Hakknda makaleler Manuals, Guides & Specifications for Technicians | Userequip. The unit plus an inverter draw 1.35 A so a 120 A/hr battery would last 3.5 days. : zet: Hakknda makaleler TransPort PT878 - Instrumart. gncelleniyor Arama sonularn eletirin: Para assegurar o funcionamen to seguro do PT878, deve instal-lo e utiliz-lo tal como descrito neste manual. Diagnostics And Troubleshooting, Page 222: Displaying Diagnostic Parameters, Page 255: Appendix B. Get the most out of your PT878 portable liquid ultrasonic flowmeter. Poor coupling to pipe. TransPort Portable Liquid Flowmeter. zet: Hakknda makaleler TransPort PT878 - dam.bakerhughesds.com. Prepare for your tests by watching these training videos, each focusing on a key function of your testing process, from startup to reporting. The Energy Option also needs to be enabled as does the appropriate scaling of the analogue input. What is the pipe made of and what is the sound speed in that material?
Transducer Tab 1. Please note, some accessories shown in the video are not included in RAECO Rents' flowmeter kit. Are there 5 pipe diameters downstream from where the flowmeter is to be mounted? ACr5|}U?h H<8H:cq`EA3` H! Ensuring There Is Flow in a Pipe Carrying Fuel Oil Prior To Welding Excessive build-up of scale, rust, or debris will interfere with flow measurement.
O PT878 e os seus transdutores so concebidos apenas Makaleye balant: https://phohen.com/tr/post-detail/ge-sensing--inspection-technologies---instrumart/518933507. In some cases different transducers may be used that protrude into the flow stream. @{) 2h,Lgh3% $ -O({U%v8. gncelleniyor To ensure the safe operation of the PT878, you must install and operate it as described in this manual. I have found that good quality high temp wheel bearing grease is usually a suitable alternative. The following are applications using the PT878 flow meter where nitrogen gas flow has been measured: Measuring Flow in a Pipe Carrying Superheated Steam The sound speed can be determined using the Sound Speed and Kinematic Viscosity table (pdf), Also, if the pipe material is not amongst the standard pipe material pre-loaded in the device, you may need to use the sound speed information in the Pipe Material Sound Speed table (pdf). gncelleniyor Makaleye balant: https://phohen.com/tr/post-detail/transport-pt878---instrumart/518933500. The TransPort PT878's patented Correlation Transit-Time digital signal processing (DSP) technique greatly increases its signal-to-noise ratio for accurate, drift-free flow measurement in liquids that contain a second phase of entrained solids or gas bubbles. 0 This video walks you through calibrating the thickness gauge and testing the results, so you know your pipe measurement will be accurate. Makaleye balant: https://phohen.com/tr/post-detail/tutorial-ge-panametrics-transport-pt878-portable-ultrasonic-/518933513. The inside of the pipe or flowcell must be relatively clean. Glycerin can give a few extra dB of coupling (it can sometimes help obtain useful readings when there seems to be no reason why it won't work) as its acoustic impedance is similar to plastics, but it can cause corrosion and or rusting so it must be completely removed. 0000016103 00000 n The TransPort PT878 operates in these and other difficult applications where conventional transit time flow meters fail. The calibration is done in the 'Setup>Calibrate' menu The GE Panametrics TransPort PT878's compact size, lightweight, rechargeable internal battery pack and universal power supply charger make it the ideal go-anywhere flow meter. gncelleniyor Para assegurar o funcionamen to seguro do PT878, deve instal-lo e utiliz-lo tal como descrito neste manual. This video explains how to install clamp-on ultrasonic transducers onto a pipe, using the information you programmed into the system based on pipe size and thickness, media type and temperature, and pipe traverses. 0000003549 00000 n Para alm disso, certifique-se de que todos os cdigos de segurana aplicveis e regulaes para instalao de equipamento elctrico na sua rea so respeitados. 2. Unless You are Prepared, Demonstration: How to Make Your TSI Quest Edge Dosimeter Microphone Last Longer, Demonstration: Setting Up TSI DusTrak Enclosures, Regional Emphasis Program for Transportation Tank Cleaning Operations, Protecting Workers Exposed to Wildfire Smoke, California EPA Community Air Monitoring Plan Guidance, Oregon OSHA Emergency Heat Illness Prevention, CDPH Frequently Asked Questions for Contractors, Tutorial: GE Panametrics TransPort PT878 Portable Ultrasonic Flowmeter. zet: Hakknda makaleler Atec PT878 User Manual - ManualMachine.com. The TransPort PT878 is suited for all standard transit Makaleye balant: https://phohen.com/tr/post-detail/ge-panametrics-transport-pt878-flowmeter--atec/518933510. Pipe Sizes 0.5 in to 300 in (12.7 mm to 7.6 m) and larger Makaleye balant: https://phohen.com/tr/post-detail/transport-pt878---veronics/518933515. gncelleniyor Arama sonularn eletirin: interface with multiple Panametrics instruments. endstream endobj startxref Programming Meter Settings, Page 133: Changing Date And Time Appearance, Page 139: Changing Communications Settings, Page 142: Resetting Forward And Reverse Totals, Page 146: Taking A Bitmap Capture Of A Current Screen, Page 156: Copying (Cloning) A Selected Log, Page 166: Displaying Log Data In Graphical Form, Page 169: Displaying Log Data In Spreadsheet Form, Page 178: Measuring Thickness In Numeric Format, Page 179: Displaying The Receive Signal In Graphical Format, Page 181: Calibrating The Thickness Gauge Transducer, Page 184: Calculating Velocity (Pipe Material Soundspeed), Page 186: Programming The Thickness Gauge, Page 189: Displaying Diagnostic Parameters, Page 190: Calibrating The Analog Output And Inputs, Page 206: Testing The Watchdog Timer Circuit, Page 208: Taking Wave Samples For Diagnosis, Page 210: Resetting To Factory Default Parameters, Page 219: Chapter 9.